ENHANCE UltraStor RS16 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Festplatten-Arrays ENHANCE UltraStor RS16 herunter. ENHANCE UltraStor RS16 User manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
UltraStor
RS16
SCSI Ultra 320 to SATA IIa
RAID Controller
User Manual
Version 3.0 (MAY. 2006)
Enhance technology UltraStor RS16
- 1 -
Seitenansicht 0
1 2 3 4 5 6 ... 59 60

Inhaltsverzeichnis

Seite 1 - RAID Controller

UltraStor RS16 SCSI Ultra 320 to SATA IIa RAID Controller User Manual Version 3.0 (MAY. 2006) Enhance technology

Seite 2 - Preface

2.3 Management methods There are three management methods to manage S Series controllers, describe on the following: 2.3.1 Web GUI S Series contr

Seite 3

Tips It does not support telnet to connect for remote control, only ssh. Using ssh, the IP address has to be setup and the password is required fo

Seite 4

The following is LCM menu hierarchy. [Alarm Mute] [cYes Nod] [Reset] [cYes Nod] [Reset/Shutdown] [Shutdown] [cYes Nod] Volume Si

Seite 5 - Chapter 1 RAID introduction

2.4.1 System buzzer The system buzzer features are describing on the following: 1. The system buzzer will alarm 3 seconds when system boots up suc

Seite 6 - 1.2 Terminology

Chapter 3 Web GUI guideline 3.1 S-series GUI hierarchy Quick Install ÆStep 1 / Step 2 / Step 3 / Confirm System Config System nameÆSystem

Seite 7

3.2 Login UltraStor series controller supports graphic user interface to manage the system. Be sure to connect LAN cable. The default IP is 192.168.0

Seite 8 - 1.3 RAID levels

3.3 Quick install It is easy to use “Quick install” function to create a volume. Depend on how many physical disks or how many residual spaces on cr

Seite 9 - Chapter 2 Getting started

Figure 3.3.2 (Figure 3.3.2: A RAID 0 user data volume with the UDV name “QUICK20680”, named by the system itself, with the total available volume si

Seite 10 - 2.3 Management methods

Figure 3.4.1 3.4.1 System name Select “System name” to change system name. Default system name composed by model name and serial number of this

Seite 11 - 2.4 Enclosure

Select “IP address” to change IP address for remote administration usage. There are 2 selections, DHCP (Get IP address from DHCP server) or set stati

Seite 12

Preface About this manual This manual is designed for UltraStor RS16 series controller user to operate the disk array system as easy as possible. I

Seite 13 - 2.4.1 System buzzer

3.4.5 Mail Select “Mail” to enter at most 3 mail addresses for receiving the event notification. Some mail servers would check “Mail-from address”

Seite 14 - Chapter 3 Web GUI guideline

3.4.7 Event log Select “Event log” to view the event messages. Press “Clear” button will clear event log. Press “Mute” button will stop alarm if syst

Seite 15 - 3.2 Login

Figure 3.5.1 3.5.1 Volume relationship diagram VGPD 2 PD 3 DS PD 1 UDV 1 UDV 2 Snap UDV Global CV +LUN 1 LUN 2 LUN 3++Dedica

Seite 16 - 3.3 Quick install

4. The operations of the other web pages (e.g.: volume config of VG, UDV, CV, LUN pages) are similar. Figure 3.5.2.1 (Figure 3.5.2.1: Physical di

Seite 17 - 3.4 System configuration

“DEFECT” Æ the hard drive has the bad blocks. “FAIL” Æ the hard drive cannot work in the respective volume. Status 1 “RD” Æ RAID Disk. This hard d

Seite 18 - 3.4.2 IP address

Figure 3.5.3.1 (Figure 3.5.3.1: There is a RAID 0 with 2 physical disks, named “VG-R0”, total size is 152064MB, free size is 52096MB, related to 1

Seite 19 - 3.4.4 Date

Status 3 “M” Æ Migration. This volume group is doing migration. RAID The RAID level, which this volume group is using. The blue square button next t

Seite 20 - 3.4.6 SNMP

3.5.4 User data volume Enter “User data volume” function to view the status of each user data volume. Figure 3.5.4.1 (Figure 3.5.4.1: Create a

Seite 21 - 3.5 Volume configuration

Status 1 “WT” Æ Write Through. “WB” Æ Write Back. The blue square button in below to the status1 is “Set read/write mode” function. Status 2 “HI” Æ

Seite 22 - 3.5.2 Physical disk

CREATE Create a user data volume function. DELETE Delete this user data volume function. 3.5.5 Cache volume Enter “Cache volume” function to view t

Seite 23

Table of Contents Chapter 1 RAID introduction...5 1.1 Features...

Seite 24 - 3.5.3 Volume group

• CV operations description: CREATE Create a cache volume function. DELETE Delete this cache volume function. 3.5.6 Logical unit number Enter “L

Seite 25

3.5.7 Examples Take 2 examples to create volumes. Example 1 is to create two UDVs shared the same CV (global cache volume) and set a global spare dis

Seite 26

(Figure 3.5.7.2: Creating a RAID 5 with 4 physical disks, named “VG-R5”. The total size is 228096MB. Because of no related UDV there, free size still

Seite 27 - 3.5.4 User data volume

(Figure 3.5.7.4: Create UDVs named “UDV-R5-1” and “UDV-R5-2”, related to “VG-R5”, the size of “UDV-R5-1” is 9984MB (it’s multiple of base stripe heig

Seite 28

Caution Be careful to avoid conflicts between SCSI ID at the same SCSI bus. Step 4: Set global spare disk. To set global spare disks, pleas

Seite 29 - 3.5.5 Cache volume

Figure 3.5.7.8 1. Select UDVs by clicking the checkbox of the row, then click “”. There will pop up a confirm page. 2. Choose “OK”. 3. Done. Step

Seite 30 - 3.5.6 Logical unit number

Tips The action of deleting one VG will succeed only when all of the related UDV(s) are empty in this VG. Otherwise, it will have an error when del

Seite 31 - 3.5.7 Examples

Figure 3.5.7.9 1. Select “/ Volume config / Cache volume”. 2. If there is no free space for creating a new dedicated cache volume, cut down the glob

Seite 32

2. Click “ ”. 3. Input a UDV name, choose a VG Name, select Dedicated cache which is created at Step 1, and input a size to be used; decide the strip

Seite 33

To set dedicated spare disks, please follow the procedures: 1. Select “/ Volume config / Physical disk”. 2. Select a VG from the list box, then sel

Seite 34 - Figure 3.5.7.7

Chapter 4 Advanced operation...47 4.1 Rebuild...

Seite 35 - Figure 3.5.7.8

2. Select the dedicated spare disk by clicking the checkbox of the row, then click “ “ to free disk. Step 11: Delete dedicated cache volume. To del

Seite 36 - • Example 2

Figure 3.6.1 3.6.1 SAF-TE configuration SAF-TE represents SCSI Accessed Fault-Tolerant Enclosures, one of the enclosure management standards. E

Seite 37 - Figure 3.5.7.10

3.6.2 Voltage and Temperature Enter “Voltage & Temperature” function to view the information of current voltage and temperature. Figure 3.6.2.

Seite 38

3.6.3 Hard drive S.M.A.R.T. function support S.M.A.R.T. (Self-Monitoring Analysis and Reporting Technology) is a diagnostic method for hard drives t

Seite 39 - Figure 3.5.7.13

Figure 3.6.4.1 Currently, the system only support and communicate with smart-UPS function of APC (American Power Conversion Corp.) For UPS, Please t

Seite 40 - 3.6 Enclosure management

“Batteries failed. Please change them NOW!” Battery Level (%) Current percentage of battery level. 3.7 System maintenance “Maintenance” function al

Seite 41 - 3.6.1 SAF-TE configuration

3.7.2 Info Enter “Info” function will display firmware version. 3.7.3 Shutdown Enter “Shutdown” function; it will display “REBOOT” and “S

Seite 42

Chapter 4 Advanced operation 4.1 Rebuild If one physical disk of the VG which sets to protected RAID level (e.g.: RAID 3 or RAID 5) is FAILED or has

Seite 43 - 3.6.4 UPS

RAID 3 Striping with parity on the dedicated disk. RAID 3 allows one hard drive fails or plugs out. RAID 5 Striping with interspersed parity over the

Seite 44 - Figure 3.6.4.1

4. Double check the setting of RAID level and RAID PD slot. If no problem, click “ “. 5. Finally a confirm page is shown with detail RAID info. If n

Seite 45 - 3.7 System maintenance

Chapter 1 RAID introduction 1.1 Features UltraStor RS16 controller is a high-performance RAID controller. • Backplane solution o UltraStor RS16: U

Seite 46 - 3.8 Logout

Tips Executing migration/expansion, the total size of VG must be larger or equal to the original VG. It does not allow expanding the same RAID leve

Seite 47 - Chapter 4 Advanced operation

Tips The size of UDV extension must be larger than original. Caution UDV extension cannot be executed during rebuild or migration. 4.4 Sn

Seite 48

4.4.1 Create snapshot volume To take a snapshot of the data, please follow the procedures. 1. Select “/ Volume config / User data volume”. 2. Choo

Seite 49

created as name “snap1”(first), “snap2” and “snap3”(last). When deleting “snap2”, both of “snap1” and “snap2” will be deleted because “snap1” are rela

Seite 50 - 4.3 UDV Extension

Tips Daily snapshot will be taken at every 00:00. Weekly snapshot will be taken on every Monday 00:00. 4.4.3 Rollback The data in snapshot UDV c

Seite 51 - Figure 4.4.1

1. Check the firmware of two systems first. It’s better that both have same firmware version or newer. 2. Whole physical disks of related VG should

Seite 52

Vendor Model Hitachi Deskstar 7K250, HDS722580VLSA80, 80GB, 7200RPM, SATA, 8M Hitachi Deskstar 7K80, HDS728080PLA380, 80GB, 7200RPM, SATA-II, 8M

Seite 53 - 4.4.2 Auto snapshot

• HDD IO events Level Type Description Warning Disk error Error: Disk <slot> read block error. Warning Disk error Error: Disk <slot>

Seite 54 - 4.5 Disk roaming

• System config events Level Type Description Info Sys Config. Defaults Restored Info: Default system configurations restored. Info Sys NVRAM OK

Seite 55 - Appendix

Warning UDV Degraded Warning: UDV <name> is under degraded mode. Info UDV Init OK Info: UDV <name> completes the initialization. Warnin

Seite 56 - B. Event notifications

UltraStor controller is the most cost-effective disk array controller with completely integrated high-performance and data-protection capabilities tha

Seite 57 - Environmental events

C. Known issues 1. In Microsoft Windows server 2003 or Windows XP, there is at least a LUN 0 in each SCSI ID; otherwise, it cannot be recognized. W

Seite 58 - LVM events

GUI Graphic User Interface. RAID width, RAID copy, RAID row (RAID cell in one row) RAID width, copy and row are used to describe one VG. E.g.: 1. On

Seite 59 - Snapshot events

SAF-TE SCSI Accessed Fault-Tolerant Enclosures. 1.3 RAID levels Describe RAID levels as follows: RAID 0 Disk striping. RAID 0 needs at least one h

Seite 60 - C. Known issues

Chapter 2 Getting started 2.1 Before starting Before starting, prepare as follows.  Review the “Certification list” in Appendix A to confirm that

Kommentare zu diesen Handbüchern

Keine Kommentare